Sectional Rail Coupling I Type PKV

PDF download

vertical linear coupling for automatic or manual clamping

sectional rail coupling type PKV

 

 

 

 

 

 

 

 

materials: tempered steel – nitrated

Technical data and dimensions [mm]: measure of length according to DIN ISO 2768 mH

Type* operating forces
FB / FBmin / FR / FRmin
[kN] / [kN] / [kN] / [kN]
** bending
moment
[Nm]
TA
(PKV-M)
[Nm]
weight
[kg]
couple
distance
K
compen-
sation
hor. / ver.
dimensions [mm]
width / heighth / length
A / B / C
bore pattern
D / E
PKV-M-80x80
PKV-P-80x80
20 / - / 25 / -
12,5 (18) / 3 / 20 (30) / 4,5
1000
1000
20
-
2,5
2,6
71
71
1,5 / 1,5
1,5 / 1,5
80 / 80 / 75
80 / 80 / 80
4x M8 / 66
4x M8 / 66
PKV-M-100x100
PKV-P-100x100
30 / - / 35 / -
20 (27) / 4 / 30 (40) / 6
2000
2000
25
-
4,8
4,8
91
89
2,5 / 2
2,5 / 2
100 / 100 / 91
100 / 100 / 95
4x M10 / 82
4x M10 / 82
PKV-M-120x120
PKV-P-120x120
40 / - / 60 / -
30 (45) / 6,5 / 50 (70) / 10,5
3000
3000
30
-
8
8,7
105
105
2 / 2
2,5 / 2
120 / 120 / 109
120 / 120 / 120
4x M12 / 100
4x M12 / 100
PKV-M-140x140
PKV-P-140x140
60 / - / 80 / -
40 (60) / 8,5 / 65 (90) / 14
6500
6500
35
-
12
12
122
122
2,5 / 2,5
3 / 2,5
140 / 140 / 120
140 / 140 / 134
4x M14 / 115
4x M14 / 115
PKV-M-160x160
PKV-P-160x160
70 / - / 100 / -
50 (75) / 11 / 80 (120) / 17,5
7500
7500
40
-
18
18
135
135
3 / 2,5
3 / 2,5
160 / 160 / 137
160 / 160 / 145
4x M16 / 132
4x M16 / 132
PKV-M-180x180
PKV-P-180x180
80 / - / 130 / -
60 (95) / 17 / 100 (150) / 28
13000
13000
50
-
25
26
154
154
4 / 3
4 / 3
180 / 180 / 152
180 / 180 / 164
4x M20 / 148
4x M20 / 148
PKV-M-200x200
PKV-P-200x200
80 / - / 130 / -
75 (115) / 17 / 125 (190) / 28
15000
15000
50
-
29
35
168
168
4 / 3
5 / 3,5
200 / 200 / 164
200 / 200 / 184
4x M20 / 168
4x M20 / 168

* FB – tolerable axial operating force at nominal pressure PN = 6 bar (10 bar)
FBmin – minimal operating force at no pressure P=0 bar
FR – tolerable vertical locking force at PN= 6 bar (10 bar)
FRmin – minimal locking force at no pressure P=0 bar
** tolerable operating values M x / y / z at nominal pressure PN=6 bar

Please note: version with customer-specific energy coupling for supplying the changing rail with power, air booster (does not belong to the scale of delivery) for 10 bar operating pressure or different sectional profiles (A x B) on demand.

order example: sectional rail coupling (1*) PKV – P – (2*) 140 x 140 – (3*) active part

(1*) „P“ – automatic clamping (pneumatic) / „M“ – manual clamping
(2*) Size 140 x 140 – sectional profile
(3*) active part / passive part